FT-1500M_align

FT-1500M_align新质力文库 - 聚焦新质生产力发展的数字化知识库_行业洞察 / 理论成果 / 实践指南免费下载新质力文库
FT-1500M_align
此内容为付费资源,请付费后查看
2333
立即购买
您当前未登录!建议登陆后购买,可保存购买订单
付费资源

第1页 / 共5页
试读已结束,还剩4页,您可下载完整版后进行离线阅读
THE END
1500M SERVICE MENU ALIGNMENT INSTRUCTIONSAlignmentIntroductionO RF Signal Generator with calibrated output level at 200The FT-1500M has been carefully aligned at the facto-MHzry for the specified performance across the amateur band.O Deviation Meter (linear detector)Realignment should therefore not be necessary except inO AC Voltmeterthe event of a component failure.All component replace-OSINAD Meterment and service should be performed only by an autho-OInline Wattmeter with 5%accuracy at 200 MHzrized Yaesu representative,or the warranty policy maybe voided.Regulated DC Power Supply:adjustable from9 to 16.5VDC,15AThe following procedures cover the sometimes critical50-Ohm Non-reactive Dummy Load:100 W at 200 MHzand tedious adjustments that are not normally requiredonce the transceiver has left the factory.However,if dam-OFrequency Counter:0.1 ppm accuracy at 200 MHzOAF Signal Generatorage occurs and some parts are replaced,realignment mayO DC Voltmeter:high impedancebe required.If a sudden problem occurs during normalOVHF Sampling Coupleroperation,it is likely due to component failure;realign-OAF Dummy Load:4-Ohms,5Wment should not be done until after the faulty componenthas been replaced.Alignment Preparation PrecautionsWe recommend that servicing be performed only byA dummy load and inline wattmeter must be connect-authorized Yaesu service technicians who are experienceded to the main antenna jack in all procedures that call forwith the circuitry and fully equipped for repair and align-transmissior.,except where specified otherwise.Correctment.Therefore,if a fault is suspected,contact the dealeralignment is not possible with an antenna.After complet-from whom the transceiver was purchased for instructionsing one step,read the following step to determine wheth-regarding repair.Authorized Yaesu service technicianser the same test equipment will be required.If not,re-realign all circuits and make complete performance checksmove the test equipment (except dummy load and watt-to ensure compliance with factory specifications after re-meter,if connected)before proceeding.placing any faulty components.Those who do undertakeCorrect alignment requires that the ambient tempera-any of the following alignments are cautioned to proceedture in the repair shop be the same as that of the trans-at their own risk.Problems caused by unauthorized at-ceiver and test equipment,and that this temperature betempts at realignment are not covered by the warrantyheld constant between 20 and 30C (68~86F).Whenpolicy.Also,Yaesu must reserve the right to change cir-the transceiver is brought into the shop from hot or coldcuits and alignment procedures in the interest of improvedair it should be allowed some time for thermal equaliza-performance,without notifying owners.Under no circum-tion with the environment before alignment.If possible,stances should any alignment be attempted unless thealignments should be made with oscillator shields andnormal function and operation of th
喜欢就支持一下吧
评论 抢沙发

请登录后发表评论

    请登录后查看评论内容