

第1页 / 共2页
试读已结束,还剩1页,您可下载完整版后进行离线阅读
THE END
GENERALIRT-206 Gun-style Infrared Thermometer1.Introduction3.SpecificationsThank you for purchasing this infrared thermometer.Temperature RangeThis infrared thermometer is a non-contact infrared-4t0605℉(-20°to320℃temperature measuring instrument.Features include aAccuracy±2%of reading or±2℃4 digits backlit LCD,scan/hold function and auto powerwhichever is greateroff(6 second).To measure a temperature,point the unitThermopile5-14μmat the object,pull the measuring trigger and hold.MakeRepeatability±1℃(±2F)sure the target area is larger than the unit's spot size.Response Time500ms.2.Safety InformationOperation Temp.32°to122F(0°o50℃),10-90%RHRead the following safety infommation carefully beforeAuto Power OffAutomatically after approx.6 sec.attempting to operate or service the meter.OnlyEmissivityFixed at 0.95qualified personnel should perfom repairs or servicingStorage Temp.14°to140°℉-10°to60℃not covered in this manual.oFo℃SwitchableYES2-1 Cautions!BacklightYESDO NOT submerge the unit in water.Laser Sight Switchable YESThis product is not designed for use in medicalBattery Type“gW"batteryevaluations.The product can only be used toBattery Life16 hrsmeasure body temperature simply for reference.Dimension5.9x3.8”x1.3"(150x133X45mm)They are meant for industrial and scientific purposes.Weight6oz.(135g)Approx.LASER WARNING NOTE!Accessory"9V"battery,Instruction manualDo not point laser directly at eye.Use caution around reflective surfaces.4.Operation of InstrumentKeep out of reach of children.4-1 Quick Start2-2 Safety symbolsTo measure a temperature,point the unit at the target△meter.Dangerous,refer to this manual before using theyou want to measure,pull the trigger and hold.Be sureto consider the target area inside the angle of vision ofthis instrument.The single spot of laser is used forC€CE Certification..aiming only.This instrument confomms to the following standards:The unit is powered by "9V"battery and displaystemperatures in either F or C.EN61326:Electrical equipment for measurement,controlReplace the battery when the battery voltage dropsand laboratory use.below the voltage for reliable operation and the lowIEC61000-4-2:Electrostatic discharge immunity test.battery symbol appears.IEC61000-4-3:Radiated,radio-frequency,electromagnetic field immunity test.SCAN/HOLDIEC61000-4-8:Power frequency magnetic field immunitytest.Battery LowLaser ONOFF Indication.C/F Switch IndicationTests were conducted using a frequency range of80-1000MHz with the instrument in three orientations.Temperature DisplayThe average error for the three orientations is +1.0F(+0.5C)at 3V/m throughout the spectrum.However,between 781-1000MHz at 3V/m,the instrument may℃F SwitchLaser ONOFF Switchnot meet its stated accuracy.5.MaintenanceNOTE:Cleaning the lens:Blow off loose particles using cleanDO NOT use solvents to clean the glass lens.compressed air.Gently brush remaining debris swaywith a camel's hair brush.Carefully wipe the surfaceCleaning the housing:with a moist cotton swab.Th
请登录后查看评论内容