ESER10MaintenanceERESSOREN10.8Change the air filterPreconditionThe power supply isolating device is switched off.the device is locked off.a check has been made that no voltage is present.1.Check the heat exchanger visually for leaks.2.Have KAEER Service check the heat excanger for insnd ncoaminated.10.8Change the air filter量Check that all sealing surfaces match each other.The use of an unsuitable air filter elementcan permit dirt to ingress the pressure system and cause damage to the machine.Do not clean the air filter element.A damaged air filter element can permit dirt to ingress thepressure system and cause damage to the machine.MaterialSparesPreconiion The supply disconecting device is switched off.the device is locked off.a check has been made that no voltage is present.The machine has cooled down.10-50058Fig.26 Air filter maintenance②Air filter element固Cover plate④NutAccess panel1.Remove the access panel(⑥,2.Remove the cover plate 53.Unscrew the nut 4 and remove the filter element.4.Clean all parts and sealing surfaces.5.Insert the new element and secure with the nut4.6.Screw the cover plate 5 onto the machine.7.Close all access doors and replace all enclosure panels.8.Switch on the power supply and reset the maintenance interval counter.编EService Manual Screw CompressorDSD SIGMA CONTROL