MOTION SENSOR MS-100INSTALLATION INSTRUCTIONS1.GENERALThe MS-100 measures ship's rolling and pitching angles with sensors using the principles of the gyroscope.Following in the footsteps ofits predecessor model BS-704,the MS-100 is free from errors caused by ship's verticaland horizontal motions and can be installed at any convenient location.However ship's semi-permanent inclination duc to loading imbalance,etc.can not be detected and should becompensated at installation as described in these instructions.2.REMARKS ON INSTALLATION2.1.Installation SiteBasically,the unit can be installed at any location,provided that the following places are avoided.Especially payattention to vibration,which may be the main cause of erroneous reading.The recommended place is on the floorin the bridge.1 Place subjected to intense vibration;engine room,thin bulkhead,ceiling,etc.2 Place exposed to rain and splash③Place with high temperature(0℃or more)Further,do not mount it on the hull unit,where intense vibration is expected.In the CSH-5,it may be unavoidable that the MS-100 is installed in the engine room since it is connccted to thetransceiver unit.Select a location where the vibration is minimal.2.2.InstallationOrient the FORE mark on the unit toward the ship's bowand mount the unit level to within 5 in all directions.Bow0≤5°FORE!AFT2.3.ConnectionCable 1Sonar 1MS-100Cable 2Sonar 2Note:Cable 2 is optional;type S06-6-10 (5-5P),code no.006-591-760.PUB.NO.IME-12780-E(9409,KAKI)MS-1000008251100